Scripps VIVO scripps research logo

  • Index
  • Log in
  • Home
  • People
  • Organizations
  • Research
  • Events
Search form

Search of sequence databases with uninterpreted high-energy collision-induced dissociation spectra of peptides

Academic Article
uri icon
  • Overview
  • Identity
  • Additional Document Info
  • View All
scroll to property group menus

Overview

authors

  • Yates III, John
  • Eng, J. K.
  • Clauser, K. R.
  • Burlingame, A. L.

publication date

  • November 1996

journal

  • Journal of the American Society for Mass Spectrometry  Journal

abstract

  • We have broadened the utility of the SEQUEST computer algorithms to permit correlation of uninterpreted high-energy collision-induced dissociation spectra of peptides with all sequences in a database. SEQUEST now allows for the additional fragment ion types observed under high-energy conditions. We analyzed spectra from peptides isolated following trypsin digestion of 13 proteins. SEQUEST ranked the correct sequence first for 90% (18/20) of the spectra in searches of the OWL database, without constraint by enzyme cleavage specificity or species of origin. All false-positives were flagged by the scoring system. SEQUEST searches databases for sequences that correspond to the precursor ion mass ±0.5 u. Preliminary ranking of the top 500 candidates is done by calculation of fragment ion masses for each sequence, and comparison to the measured ion masses on the basis of ion series continuity, summed ion intensity, and immonium ion presence. Final ranking is done by construction of model spectra for the 500 candidates and constructing/performing of a cross-correlation analysis with the actual spectrum. Given the need to relate mounting genome sequence information with corresponding suites of proteins that comprise the cellular molecular machinery, tandem mass spectrometry appears destined to play the leading role in accelerating protein identification on the large scale required.
  • We have broadened the utility of the SEQUEST computer algorithms to permit correlation of uninterpreted high-energy collision-induced dissociation spectra of peptides with all sequences in a database. SEQUEST now allows for the additional fragment ion types observed under high-energy conditions. We analyzed spectra from peptides isolated following trypsin digestion of 13 proteins. SEQUEST ranked the correct sequence first for 90% (18/20) of the spectra in searches of the OWL database, without constraint by enzyme cleavage specificity or species of origin. All false-positives were flagged by the scoring system. SEQUEST searches databases for sequences that correspond to the precursor ion mass �0.5 u. Preliminary ranking of the top 500 candidates is done by calculation of fragment ion masses for each sequence, and comparison to the measured ion masses on the basis of ion series continuity, summed ion intensity, and immonium ion presence. Final ranking is done by construction of model spectra for the 500 candidates and constructing/performing of a cross-correlation analysis with the actual spectrum. Given the need to relate mounting genome sequence information with corresponding suites of proteins that comprise the cellular molecular machinery, tandem mass spectrometry appears destined to play the leading role in accelerating protein identification on the large scale required.
scroll to property group menus

Identity

International Standard Serial Number (ISSN)

  • 1044-0305

Digital Object Identifier (DOI)

  • 10.1016/s1044-0305(96)00079-7

PubMed ID

  • 24203070
scroll to property group menus

Additional Document Info

start page

  • 1089

end page

  • 1098

volume

  • 7

issue

  • 11

©2021 The Scripps Research Institute | Terms of Use | Powered by VIVO

  • About
  • Contact Us
  • Support