Scripps VIVO scripps research logo

  • Index
  • Log in
  • Home
  • People
  • Organizations
  • Research
  • Events
Search form

Towards protein-crystal centering using second-harmonic generation (SHG) microscopy

Academic Article
uri icon
  • Overview
  • Identity
  • Additional Document Info
  • View All
scroll to property group menus

Overview

authors

  • Kissick, D. J.
  • Dettmar, C. M.
  • Becker, M.
  • Mulichak, A. M.
  • Cherezov, Vadim
  • Ginell, S. L.
  • Battaile, K. P.
  • Keefe, L. J.
  • Fischetti, R. F.
  • Simpson, G. J.

publication date

  • 2013

journal

  • Acta Crystallographica Section D-Biological Crystallography  Journal

abstract

  • The potential of second-harmonic generation (SHG) microscopy for automated crystal centering to guide synchrotron X-ray diffraction of protein crystals was explored. These studies included (i) comparison of microcrystal positions in cryoloops as determined by SHG imaging and by X-ray diffraction rastering and (ii) X-ray structure determinations of selected proteins to investigate the potential for laser-induced damage from SHG imaging. In studies using β2 adrenergic receptor membrane-protein crystals prepared in lipidic mesophase, the crystal locations identified by SHG images obtained in transmission mode were found to correlate well with the crystal locations identified by raster scanning using an X-ray minibeam. SHG imaging was found to provide about 2 µm spatial resolution and shorter image-acquisition times. The general insensitivity of SHG images to optical scatter enabled the reliable identification of microcrystals within opaque cryocooled lipidic mesophases that were not identified by conventional bright-field imaging. The potential impact of extended exposure of protein crystals to five times a typical imaging dose from an ultrafast laser source was also assessed. Measurements of myoglobin and thaumatin crystals resulted in no statistically significant differences between structures obtained from diffraction data acquired from exposed and unexposed regions of single crystals. Practical constraints for integrating SHG imaging into an active beamline for routine automated crystal centering are discussed.

subject areas

  • Animals
  • Crystallography, X-Ray
  • Horses
  • Image Processing, Computer-Assisted
  • Microscopy
  • Myoglobin
  • Protein Conformation
  • Proteins
  • Receptors, Adrenergic, beta-2
  • Synchrotrons
  • X-Ray Diffraction
scroll to property group menus

Identity

PubMed Central ID

  • PMC3640472

International Standard Serial Number (ISSN)

  • 0907-4449

Digital Object Identifier (DOI)

  • 10.1107/s0907444913002746

PubMed ID

  • 23633594
scroll to property group menus

Additional Document Info

start page

  • 843

end page

  • 851

volume

  • 69